
Metal Firebox, Framed Chase? Driscoll Repairs It to the Listing, in Artesia
Panels, dampers, caps and chase tops, with brick and gas work alongside
Every card starts from one question: is this a factory-built unit, and what does its listing allow? The sweep, the insert or the brick work follows from the answer.
Chimney Sweep
Round metal pipe or clay tile, brushed with the right head and vacuumed, with dents and loose joints written down.
Chimney Inspection
Data plate first, then panels, pipe, chase top and cap, each checked against what that fireplace was tested with.
Chimney Repair
Brick or framed chase, the system type confirmed first, then fixed with mortar for one and listed metal parts for the other.
Fireplace Inspection
The prefab box compared with its own listing, so every missing panel, screen or door part is named and photographed.
Fireplace Repair
Listed panels, dampers, screens and glass fitted by model number, or an honest word when the unit has no parts left.
Chimney Level 2 Inspection
Camera footage of the boxed-in pipe, plus the chase and attic spaces we can reach, written up for $395.
Chimney Cap Installation
The listed termination for a prefab pipe, or a stainless or copper mesh cap on brick, fitted, quoted after we measure.
Chimney Flashing Repair
New step and counter metal around the base, tucked under chase siding or cut into brick, with a cricket where it is wide.
Chimney Masonry Repair
Soft joints ground out and pointed with a mix as hard as the old brick, and broken faces swapped one at a time.
Chimney Rebuilds
A loose brick top or a rotted chase taken down and built back new, with listed pipe and a fresh chase top on prefab systems.
Fireplace Cleaning
Soft brushes and a sealed vacuum on the panels, glass and screen, with any cracked panel or open seam noted.
Gas Fireplace Cleaning
The manual's own service list for a sealed gas unit: glass, pilot, burner, log layout and the outside hood.
Gas Fireplace Repair
Meter readings against the manual, one part at a time, then only the failed piece replaced with one made for that model.
Fireplace Remodel
Surround, mantel and hearth planned to the listing's clearances, with the unit priced for replacement if it is worn out.
Fireplace Inserts
An insert only where the fireplace manual allows one, with a full liner and gas hookup, from $2,800 to $5,650 installed.
Pellet Stove Repair
The error code read first, then switches, blowers, auger and igniter tested, and the failed one replaced to the model.
Wood Stove Repair
The stove's label checked against the room, pipe and floor pad, and worn inside parts replaced with ones for that model.
Gas Logs
A log set only where the manual approves one, with the burner, gas line and open damper the instructions call for.
Chimney Seismic Retrofit
Steel ties to the roof framing, or the heavy top replaced with a lighter framed chase and metal flue, priced in writing.
Chimney Crown Repair
Hairline cracks sealed with a flexible coating, or a thin, split crown broken off and cast again with an overhang.
Dryer Vent Cleaning
Lint cleared from the dryer to the roof or wall hood, with foil sections and crushed elbows swapped for metal duct.
Chimney Liner Installation
Stainless liner down a cracked tile flue, or failed prefab pipe swapped for the same brand and size, with a camera check after.
Chimney Leak Repair
The stain followed back to the chase top, storm collar, siding or flashing, then closed, for $565 to $3,350.
Chimney Waterproofing
A vapor-permeable product suited to brick, stucco or siding, put on only after the crown, flashing and chase top are sound.
Chimney Damper Repair
Maker's parts for a prefab damper, or a cast iron throat freed or swapped for a top-sealing unit on brick.
Chimney Chase Cover
A made-to-measure top with a raised center, a skirt over the siding and a collar cut to the pipe.
Sales, escrow, estates and quake repairs
Four kinds of job come to us with a deadline or a third party attached. Each page below says what we look at on a factory-built or brick fireplace in that situation, what it costs where we publish a price, and who gets the paperwork.
Condo and townhouse sales
Selling or buying a unit with a metal fireplace? We sort out which parts belong to the owner and which to the association, then inspect all of them.
Agents with repairs in escrow
A fireplace repair agreed during escrow needs a written scope both sides can sign off on. We write it, do the work, and send the proof.
Large homes and estates
Several fireplaces under one roof, priced per fireplace and inspected room by room in a single visit, with one report the owner or manager can file.
Structural and code repairs
After a failed Level 2 or a quake: the structural items first, from cracked crowns and loose brick to racked chases and separated pipe.
Based in Artesia, with Cerritos, Bellflower and Compton close by
140 city pages, each describing the houses and fireplaces we see there. Search a name to open yours.
At a Glance
140
City pages
26
Services offered
Artesia
Home base
On a street near one of these cities but not sure it is covered? Send the cross streets through the form and we confirm.
Artesia
Home turf, between the 91 Freeway and Little India
A fall or winter Santa Ana day will lift a cap held with too few screws. The 2008 and 2014 quakes, Chino Hills then La Habra, rattled the city, and shaking like that can part metal flue joints hidden in a chase.
Cerritos
Focus city of 1970s fireboxes and framed chases
Winters almost never freeze and summers are warm, so a chase top mostly suffers sun, plus Santa Ana gusts at the cap. Unreinforced masonry broke across the south county in 1933, when Long Beach shook, and framed chases move too.
Bellflower
Old Bellefleur apple orchards turned tract streets
Marine influence keeps temperatures even, with low cloud on early summer mornings, but a Santa Ana gust still pries at a weak cap. When the 1933 Long Beach quake struck, unreinforced brick failed widely in southern LA County.
Compton
Griffith Compton's 1888 city, older than its neighbors
Crowns, mortar joints and flashing take their soaking November to April, while warm summers bring no hard freeze. Wildfire has no record inside town; quake shaking from Chino Hills, 2008, and La Habra, 2014, does.
Full directory
136 more areas in our directory
Each city and the ZIPs our runs cover.
Panels, Listings, Caps and Chase Tops, Answered
What tract house owners around Artesia ask before booking. For anything else, use the contact form and name the fireplace brand if you know it.
Where are you based, and which cities do you cover?
Our base is Artesia. Cerritos, Bellflower and Compton are the cities we focus on, and the areas page lists every other city we reach. Put your cross streets on the form and we reply with a window for the visit.
How can I tell if my fireplace is factory-built?
Signs of a prefab unit: a metal box lined with thin panels rather than firebrick in mortar, a round metal pipe on the roof inside a wood or stucco box, and a metal data plate inside the firebox or behind the lower grille. A large share of houses built here from the seventies onward have one. We confirm the maker and model on the first visit.
Can a cracked panel in a prefab firebox be patched?
Usually not in a way that keeps the unit inside its listing. Most manuals give a crack width past which the panel must be replaced, and patch compound does not change that. We measure the crack, read the limit in the manual, and order matched panels by model number when the crack is past it.
What happens if the maker no longer sells parts for my unit?
Some brands from the seventies and eighties are gone, and a few of their parts have no listed substitute. When that is the case the choices are an insert that the fireplace manual approves, or removing the old box and fitting a new listed fireplace. Both are priced in writing so you can compare them.
Which inspection level should I book?
NFPA 211 names three. Level 1, at $55, covers the parts in plain reach and suits a fireplace in steady use with nothing changed. Level 2, at $395, puts a camera inside the pipe and checks the chase and attic spaces, and fits a sale, a new appliance or a quake. Level 3 means opening a wall or the chase, and is booked only when a Level 2 points to a problem behind a finished surface.
Does South Coast AQMD Rule 445 apply to my fireplace?
Artesia and the rest of Los Angeles County fall under it. Rule 445 calls no-burn days for wood during the winter season and restricts wood-burning fireplaces in new construction. Gas fireplaces and gas log sets are not subject to the no-burn days, which is one reason owners here convert. We price inserts and log sets after checking what your fireplace allows.
Should a house with a gas fireplace have carbon monoxide alarms?
Yes. California requires carbon monoxide alarms in homes with a fuel-burning appliance, and a gas fireplace counts. Fit one outside each sleeping area and one on every floor. For our part, every gas cleaning and gas repair we do ends with a reading taken at the unit, and the figure goes in your report.
My chase top has rust on it. Is that serious?
Rust means water sits on the top instead of running off. Once it rusts through, water runs down the pipe and into the chase framing, often with no stain inside until the wood has gone soft. A new chase top costs far less than reframing a chase, so it pays to replace it early. We measure it and quote the cover in writing.
Can my prefab fireplace take a gas insert?
Only if its manual says so, and many do not. Where an insert is approved, fitting one into a fireplace you already have runs $2,800 to $5,650. Where it is not, the listed route is to remove the old unit and fit a new gas fireplace. We read the manual before quoting either.
How are repairs priced?
Some work has a set price on this site: sweeps from $420, a Level 1 at $55, a Level 2 at $395 and leak repair at $565 to $3,350. Caps are quoted on site. Panels, chase tops, liners, dampers and brick work vary with the model and the size of the job, so those are quoted in writing after we have looked.
We are selling a condo with a shared chimney. Who fixes what?
It depends on the CC&Rs. In many complexes the chase, the pipe above the ceiling and the top belong to the association, while the firebox, doors and screen belong to the unit. Our report names the part behind each finding, so the owner and the HOA can see which list it falls on.
Have a question we did not answer?
Book a VisitThe Box Was Tested as a Set. We Repair It as One.
Driscoll Chimney Solutions works from Artesia, in southeast Los Angeles County, with Cerritos, Bellflower and Compton as the other cities we focus on. Many houses here have a metal fireplace from the seventies onward, set in a wood-framed chase.
Those fireplaces were tested by their makers as a full set: firebox, panels, screen, damper, pipe and cap. They stay inside that listing only while the parts match it, which is why a patch or an odd part from another brand does not count as a repair.
So each visit starts at the data plate. You see photos of each worn or missing part, a written price with part numbers, and nothing is ordered until you agree. Brick chimneys on the same streets get mortar, crown and flashing work instead.
- Plate
- Read before any part is checked
- Listed
- Panels, dampers and caps by model
- Chase
- Top and collar checked on the roof


Listing First
A factory-built fireplace is only as safe as the parts it was tested with, so its data plate shapes every repair we suggest.
Tract House Work
Artesia, Cerritos, Bellflower and Compton are full of houses with framed chases and metal fireboxes. That is the work we lead with.
Parts by Number
Panels, dampers, caps and pipe are ordered by model, never cut down from a generic kit to fit.
Price Before Parts
Every repair is written up and priced before anything is ordered, and the photos come with it.
From Your Request to a Fireplace Back in Its Listing
The order holds for an Artesia tract house with a metal box or a Compton bungalow with brick: the plate, the firebox, the roof, the quote, then the fit.
Name the Fireplace
Use the form to say what you have, a metal prefab, a brick fireplace, a gas unit or a stove, and what it is doing wrong. If you can read a brand name on the data plate, add it.
Listing Pulled
On the visit we find the data plate and look up the maker's manual, so each check is made against what that unit was tested with.
Firebox to Chase Top
Panels, screen, damper and doors come first, then the pipe, the chase and the cap on the roof. Every finding gets a photo.
Quote by Part Number
You get the findings and a written price for each fix, with part numbers where they apply. Nothing is ordered until you say yes.
Fitted and Tested
We fit the listed parts, run the fireplace, and leave you the report and the photos.
Cracked Panel, Loose Damper, Rusty Chase Top: Sorted by the Listing
What Is the Fireplace Doing?
A pilot that drops out, a panel with a crack, a damper that will not stay shut. Leave a number and we reply to set a visit.
